SIM900 AT Command Manual
SIM900_AT Command Manual_V1.03 183 12/24/2010
Parameter
<mode> a numeric parameter which indicates whether an IP header
is added to the received data or not.
0 not add IP header
1 add IP header, the format is "+IPD,data length:"
Reference
Note
This command will be effective only in single connection mode
(+CIPMUX=0) and command mode.
8.2.16 AT+CIPATS Set Auto Sending Timer
AT+CIPATS Set Auto Sending Timer
Response
+CIPATS: (list of supported <mode>s),(list of supported <time>)
OK
Test Command
AT+CIPATS=?
Parameters
See Write Command
Response
+CIPATS: <mode>,<time>
OK
Read Command
AT+CIPATS?
Parameters
See Write Command
Response
OK
ERROR
Write Command
AT+CIPATS=<m
ode>[,<time>]
Parameters
<mode> a numeric parameter which indicates whether set timer when
module is sending data
0 not set timer when module is sending data
1 Set timer when module is sending data
<time> 1..100 a numeric parameter which indicates the seconds
after which the data will be sent
Reference
Note
8.2.17 AT+CIPSPRT Set Prompt of ‘>’ When Module Sends Data
AT+CIPSPRT Set Prompt of ‘>’ When Module Sends Data